Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 4.622
1.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38647070

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
3.
Curr Opin Crit Care ; 30(3): 202-208, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38441108

PURPOSE OF REVIEW: Noncompressible torso hemorrhage (NCTH) is now considered as the major cause of preventable death after both severe military and civilian trauma. Around 20% of all trauma patients still die from uncontrolled exsanguination along with rapidly evolving hemostatic failure. This review highlights the most recent advances in the field and provides an outline for future research directions. RECENT FINDINGS: The updated definition of NCTH includes a combination of high-grade anatomical torso injury, hemodynamic instability, urgent need for hemorrhage control and aggressive hemostatic resuscitation. Therapeutic concepts consider the following three aspects: control the bleeding source (close the tap), resuscitate to maintain organ perfusion and restore hemostasis (fill the tank), and increase the body's resistance against ischemia (upgrade the armor). SUMMARY: The concepts for the early management of NCTH have substantially evolved over the last decade. The development of new devices and techniques combined with early intervention of hemostatic failure have contributed to more successful resuscitations. Future research needs to refine and validate their potential clinical application.


Hemorrhage , Resuscitation , Humans , Resuscitation/methods , Hemorrhage/therapy , Torso , Hemostatic Techniques , Exsanguination/therapy
5.
J Invasive Cardiol ; 36(5)2024 May.
Article En | MEDLINE | ID: mdl-38422529

OBJECTIVES: Patent hemostasis (PH) is essential for preventing radial artery occlusion (RAO) after trans-radial procedures; however, it remains unclear how it should be obtained. The aim of this multicenter randomized study was to evaluate whether the use of an adjustable device (AD), inflated with a pre-determined amount of air (AoA), was more effective than a non-adjustable device (non-AD) for achieving PH, thereby reducing the incidence of RAO. METHODS: We enrolled a total of 480 patients undergoing transradial procedure at 3 Italian institutions. Before the procedure, a modified Reverse Barbeau Test (mRBT) was performed in all patients to evaluate the AoA to be eventually inflated in the AD. After the procedure, patients were randomized into 2 groups: (1) AD Group, using TR-Band (Terumo) inflated with the pre-determined AoA; and 2) non-AD Group, using RadiStop (Abbott). An RBT was performed during compression to demonstrate the achievement of PH, as well as 24 hours later to evaluate the occurrence of RAO. RESULTS: PH was more often obtained in the AD Group compared with the non-AD Group (90% vs 64%, respectively, P less than .001), with no difference in terms of bleedings. RAO occurred more often in the non-AD Group compared with the AD Group (10% vs 3%, respectively, P less than .001). Of note, mRBT was effective at guiding AD inflation and identifying high-risk patients in whom PH was more difficult to obtain. CONCLUSIONS: The use of AD, filled with a predetermined AoA, allowed PH significantly more often compared with non-AD, providing a significantly reduced incidence of RAO.


Percutaneous Coronary Intervention , Radial Artery , Humans , Male , Female , Aged , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Middle Aged , Arterial Occlusive Diseases/prevention & control , Arterial Occlusive Diseases/etiology , Arterial Occlusive Diseases/diagnosis , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Incidence , Hemostasis/physiology , Italy/epidemiology , Treatment Outcome , Equipment Design
6.
Cardiovasc Revasc Med ; 62: 60-65, 2024 May.
Article En | MEDLINE | ID: mdl-38184452

PURPOSE: Mechanical circulatory support (MCS) using a venoarterial extracorporeal membrane oxygenation (VA-ECMO) device or a catheter-type heart pump (Impella) is critical for the rescue of patients with severe cardiogenic shock. However, these MCS devices require large-bore cannula access (14-Fr and larger) at the femoral artery or vein, which often requires surgical decannulation. METHODS: In this retrospective study, we evaluated post-closure method using a percutaneous suture-mediated vascular closure system, Perclose ProGlide/ProStyle (Abbott Vascular, Lake Bluff, IL, Perclose), as an alternative procedure for MCS decannulation. Closure of 83 Impella access sites and 68 VA-ECMO access sites performed using Perclose or surgical method between January 2018 and March 2023 were evaluated. RESULTS: MCS decannulation using Perclose was successfully completed in all access sites without surgical hemostasis. The procedure time of ProGlide was shorter than surgical decannulation for both Impella and VA-ECMO (13 min vs. 50 min; p < 0.001, 21 min vs. 65 min; p < 0.001, respectively). There were no significant differences in the 30-day survival rate and major adverse events by decannulation including arterial dissection requiring endovascular treatment, hemorrhage requiring a large amount of red blood cell transfusion, and access site infection. CONCLUSION: Our results suggest that the post-closure technique using the percutaneous suture-mediated closure system appears to be a safe and effective method for large-bore MCS decannulation.


Catheterization, Peripheral , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Hemostatic Techniques , Punctures , Vascular Closure Devices , Humans , Retrospective Studies , Male , Female , Treatment Outcome , Middle Aged , Aged , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Time Factors , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Device Removal/adverse effects , Suture Techniques/instrumentation , Suture Techniques/adverse effects , Femoral Artery , Shock, Cardiogenic/therapy , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/diagnosis , Risk Factors , Hemorrhage/etiology , Hemorrhage/prevention & control
7.
Catheter Cardiovasc Interv ; 103(1): 160-168, 2024 01.
Article En | MEDLINE | ID: mdl-38059295

BACKGROUND: New vascular closure devices (VCD) are being introduced for achieving hemostasis after transcatheter aortic valve implantation (TAVI). However, no safety or efficacy data have been published compared to other contemporary VCD. AIM: To compare the safety and efficacy of suture-based Perclose Prostyle as compared to plug-based MANTA device. METHODS: A total of 408 consecutive TAVI patients from two high volume TAVI centers were included in the present study. Patients were grouped according to VCD: Prostyle versus MANTA. Propensity score matching (PSM) and multivariable analysis were utilized to compare clinical endpoints between the two groups. The primary endpoint was any vascular complication (VC) according to VARC-3 criteria. RESULTS: After PSM, a total of 264 patients were analyzed, of them 132 in each group. Overall baseline characteristics of the two groups were comparable. Primary end-point was similar between MANTA as compared to Prostyle (16.7% vs. 15.3% respectively, p = 0.888). The main driver for VC among MANTA group were minor vascular complications (15.2%). Conversely, minor and major VC contributed equally to the primary endpoint among Prostyle group (7.6%) (p = 0.013). No outcome predictors were identified in multivariate analysis. CONCLUSIONS: VCD for transfemoral TAVI using the new-generation Prostyle device or the MANTA device achieved comparable VARC-3 VC rates.


Aortic Valve Stenosis , Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Catheterization, Peripheral/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Hemostatic Techniques/adverse effects
8.
J Vasc Surg ; 79(3): 569-576, 2024 Mar.
Article En | MEDLINE | ID: mdl-37923021

OBJECTIVE: The MANTA device is a plug-based vascular closure device (VCD) designed for large bore femoral arterial access site closure. It showed promising results in transcatheter aortic valve replacement cases. In this study, we report our results and evaluate the MANTA VCD in percutaneous endovascular aortic aneurysm repair (pEVAR). METHODS: All data of consecutive patients who underwent an elective pEVAR between October 2018 and December 2022 were retrospectively reviewed. In all patients at least one common femoral artery was intended to close with the MANTA VCD. Depending on the sheath size, the 14Fr or 18Fr MANTA VCD was used. On the preoperative computed tomography scan, the diameter of the common femoral artery (CFA) was measured and the amount of calcification based on the Peripheral Arterial Calcium Scoring System (PACSS) was scored. Primary outcome was procedural technical success. Procedural technical success was defined as placement of the MANTA closure device resulting in vascular closure with patent CFA, without requiring immediate open or endovascular surgery. The secondary outcomes were access site complications requiring reintervention and all-cause mortality at 30-day follow-up. RESULTS: In total, 152 consecutive patients underwent pEVAR with 291 common femoral artery closure procedures with the Manta VCD. Mean age was 74.1 ± 6.4 years, with a mean body mass index of 27.7 ± 4.4 kg/m2. The mean diameter of the CFA was 10.5 ± 1.9 mm. In 52.6% of the cases, there were no calcification on the preoperative computed tomography scan. The 18Fr and 14Fr Manta VCD were used 169 and 122 times, respectively. The technical success rate was 96.6%. Major vascular complications were reported in 4.5% of the cases, without any death-related events. CONCLUSIONS: This single-center retrospective cohort study analyzed the procedural technical success, major vascular complications and all-cause mortality at 30-day follow-up of the MANTA vascular closure device in 152 pEVAR patients with 291 common femoral artery closure procedures. The technical success rate was 96,6%. Major vascular complications were reported in 4.5% of the cases, without any death related events. We concluded that the MANTA device is a safe and feasible option with a high rate of technical success in patients undergoing pEVAR.


Aortic Aneurysm , Endovascular Procedures , Vascular Closure Devices , Humans , Aged , Aged, 80 and over , Endovascular Procedures/adverse effects , Hemostatic Techniques , Retrospective Studies , Treatment Outcome , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery
9.
J Vasc Surg ; 79(4): 740-747.e2, 2024 Apr.
Article En | MEDLINE | ID: mdl-38056701

BACKGROUND: Percutaneous access and use of vascular closure devices facilitate thoracic endovascular aortic repair (TEVAR) procedures during local anesthesia and allow immediate detection of signs of spinal ischemia. However, the very large bore access (usually ≥22F sheath) associated with TEVAR increases the risk of vascular complications. In this study, we sought to define the safety and feasibility of two percutaneous femoral artery closure devices during TEVAR, in terms of access site vascular complications and major, life-threatening, or fatal bleeding (≥major) within 48 hours. Access site vascular complications were defined as technical failure of vascular closure or later formation of pseudoaneurysm. METHODS: From March 2010 to December 2022, 199 transfemoral TEVAR were performed at Helsinki University Central Hospital, Finland. We retrospectively categorized these into three groups, based on surgeon preference for the access technique and femoral artery closure method: (1) surgical cut-down and vessel closure, n = 85 (42.7%), (2) percutaneous access and vascular closure with suture-based ProGlide, n = 56 (28.1%), or (3) percutaneous access and vascular closure with ultrasound-guided plug-based MANTA, n = 58 (29.1%). The primary outcome measure was technical success of vascular closure and access site vascular complications during index hospitalization. Secondary outcome measures were ≥major bleeding, early mortality, and hospital stay. RESULTS: The technical success rate was 97.6% vs 91.1% vs 93.1% for surgical cut-down, ProGlide, and MANTA, respectively (P = .213). The rate of access site vascular complication was 3.5% vs 8.9% vs 10.3%, respectively (P = .290), with two pseudoaneurysms detected postoperatively and conservatively managed in the MANTA group. The vascular closure method was not associated with increased risk of ≥major bleeding, early mortality, or hospital stay on univariate analysis. Predictors for ≥major bleeding after TEVAR in multivariable analysis were urgent procedure (odds ratio: 2.8, 95% confidence interval: 1.4-5.5; P = .003) and simultaneous aortic branch revascularization (odds ratio: 2.7, 95% confidence interval: 1.3-5.4; P = .008). CONCLUSIONS: In this study, the technical success rates of the percutaneous techniques demonstrated their feasibility during TEVAR. However, the number of access site complications for percutaneous techniques was higher compared with open approach, although the difference was not statistically significant. In the lack of evidence, the safety of the new MANTA plug-based vascular closure for TEVAR warrants further investigation.


Catheterization, Peripheral , Endovascular Procedures , Vascular Closure Devices , Humans , Endovascular Aneurysm Repair , Retrospective Studies , Treatment Outcome , Hemorrhage/etiology , Hemorrhage/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects
10.
Am Surg ; 90(3): 455-464, 2024 Mar.
Article En | MEDLINE | ID: mdl-37970830

BACKGROUND: Hemodynamically unstable pelvic fractures are often life-threatening injuries; however, the optimal management remains uncertain. This systematic review and meta-analysis aim to evaluate the most appropriate primary management of hemorrhage in adult patients with hemodynamically unstable pelvic fractures by comparing outcomes following the initial use of preperitoneal packing (PPP) vs angioembolization (AE). METHODS: A systematic search of PubMed, Embase, Google Scholar, and ProQuest databases was conducted following PRISMA guidelines. Studies assessing hemorrhage management in trauma patients with hemodynamically unstable pelvic fractures were included. The data extracted from selected articles included patient demographics, study design, and outcomes such as 24-hour PRBC transfusions, in-hospital mortality, and DVT rate. RESULTS: Eight articles were included in the systematic review. Among the included studies, 2040 patients with hemodynamically unstable pelvic fractures were analyzed. Meta-analyses revealed that treatment with PPP was associated with fewer 24-hour PRBC transfusions (mean difference = -1.0, 95% CI: -1.8 to -.2) than AE. However, no significant differences were noted in in-hospital mortality (RR: .91, 95% CI: .80-1.05) and the rate of deep vein thrombosis (RR: .89, 95% CI: .62-1.28) between groups. CONCLUSION: The findings of this study suggest that primary management with PPP was associated with fewer 24-hour PRBC transfusions compared to AE. The choice of primary management with PPP or AE did not significantly impact in-hospital mortality. Future studies should address clinical outcomes and the factors that affect them to better understand the impact of different management strategies and direct the creation of practice management guidelines.


Fractures, Bone , Pelvic Bones , Adult , Humans , Fracture Fixation , Fractures, Bone/complications , Fractures, Bone/therapy , Hemorrhage/therapy , Hemorrhage/complications , Pelvic Bones/injuries , Hemostatic Techniques , Retrospective Studies
11.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Article En | MEDLINE | ID: mdl-37982158

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Femoral Artery/surgery , Hemorrhage/etiology , Hemorrhage/prevention & control , Hemostatic Techniques/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Vascular Closure Devices/adverse effects
12.
J Trauma Acute Care Surg ; 96(2): 256-264, 2024 Feb 01.
Article En | MEDLINE | ID: mdl-37858305

BACKGROUND: Hemorrhage control in prolonged field care (PFC) presents unique challenges that drive the need for enhanced point of injury treatment capabilities to maintain patient stability beyond the Golden Hour. To address this, two hemostatic agents, Combat Gauze (CG) and XSTAT, were evaluated in a porcine model of uncontrolled junctional hemorrhage for speed of deployment and hemostatic efficacy over 72 hours. METHODS: The left subclavian artery and subscapular vein were isolated in anesthetized male Yorkshire swine (70-85 kg) and injured via 50% transection, followed by 30 seconds of hemorrhage. Combat Gauze (n = 6) or XSTAT (n = 6) was administered until bleeding stopped and remained within subjects for observation over 72 hours. Physiologic monitoring, hemostatic efficacy, and hematological parameters were measured throughout the protocol. Gross necropsy and histology were performed following humane euthanasia. RESULTS: Both CG and XSTAT maintained hemostasis throughout the full duration of the protocol. There were no significant differences between groups in hemorrhage volume (CG: 1021.0 ± 183.7 mL vs. XSTAT: 968.2 ± 243.3 mL), total blood loss (CG: 20.8 ± 2.7% vs. XSTAT: 20.1 ± 5.1%), or devices used (CG: 3.8 ± 1.2 vs. XSTAT: 5.3 ± 1.4). XSTAT absorbed significantly more blood than CG (CG: 199.5 ± 50.3 mL vs. XSTAT: 327.6 ± 71.4 mL) and was significantly faster to administer (CG: 3.4 ± 1.6 minutes vs. XSTAT: 1.4 ± 0.5 minutes). There were no significant changes in activated clot time, prothrombin time, or international normalized ratio between groups or compared with baseline throughout the 72-hour protocol. Histopathology revealed no evidence of microthromboemboli or disseminated coagulopathies across evaluated tissues in either group. CONCLUSION: Combat Gauze and XSTAT demonstrated equivalent hemostatic ability through 72 hours, with no overt evidence of coagulopathies from prolonged indwelling. In addition, XSTAT offered significantly faster administration and the ability to absorb more blood. Taken together, XSTAT offers logistical and efficiency advantages over CG for immediate control of junctional noncompressible hemorrhage, particularly in a tactical environment. In addition, extension of indicated timelines to 72 hours allows translation to PFC.


Hemostatics , Swine , Male , Humans , Animals , Hemostatics/therapeutic use , Disease Models, Animal , Hemorrhage/therapy , Exsanguination/therapy , Hemostasis , Hemostatic Techniques
13.
J Vet Cardiol ; 51: 124-137, 2024 Feb.
Article En | MEDLINE | ID: mdl-38128418

INTRODUCTION/OBJECTIVES: Manual compression has been standard of care for maintaining hemostasis after percutaneous endovascular intervention, but can be time-consuming and associated with vascular complications. Alternative closure methods include the figure-of-eight suture (Z-stitch) and vascular closure device (VCD) techniques. We hypothesized that compared to manual compression, Z-stitch and VCD would significantly reduce time-to-hemostasis after transvenous access, and the proportion of dogs with vascular patency would not differ significantly among treatments. ANIMALS: Forty-six client-owned dogs undergoing percutaneous transvenous interventional procedures. MATERIALS AND METHODS: Dogs with vessel diameter <5 mm were randomized to undergo manual compression or Z-stitch, while those with vessel diameter ≥5 mm were randomized to undergo manual compression, Z-stitch, or VCD. Time-to-hemostasis, bleeding scores, presence of vascular patency one day and two to three months post-procedure, and complications were recorded. Data are presented as median (95% confidence interval). RESULTS: In all 46 dogs, the right external jugular vein was used. Time-to-hemostasis was significantly shorter in the Z-stitch (2.1 [1.8-2.9] minutes) compared to VCD (8.6 [6.1-11.8] minutes; P<0.001) and manual compression (10.0 [10.0-20.0] minutes; P<0.001) groups. Time-to-hemostasis was significantly shorter in the VCD vs. manual compression (P=0.027) group. Bleeding scores were significantly greater at 5 and 10 min (P<0.001 and 0.013, respectively) in manual compression, compared to Z-stitch group. There was no difference in the proportion of dogs with vascular patency between groups (P=0.59). CONCLUSIONS: Z-stitch and VCD are effective venous hemostasis methods after percutaneous transvenous intervention, with Z-stitch providing the most rapid time-to-hemostasis. Both Z-stitch and VCD techniques have low complication rates and effectively maintain vascular patency.


Dog Diseases , Hemostatic Techniques , Postoperative Hemorrhage , Vascular Closure Devices , Vascular Surgical Procedures , Animals , Dogs , Dog Diseases/surgery , Femoral Artery/surgery , Hemostatic Techniques/adverse effects , Hemostatic Techniques/veterinary , Treatment Outcome , Vascular Closure Devices/veterinary , Vascular Closure Devices/adverse effects , Vascular Surgical Procedures/adverse effects , Vascular Surgical Procedures/instrumentation , Vascular Surgical Procedures/methods , Postoperative Hemorrhage/prevention & control , Postoperative Hemorrhage/veterinary
15.
Mil Med ; 188(Suppl 6): 280-287, 2023 11 08.
Article En | MEDLINE | ID: mdl-37948225

INTRODUCTION: Hemorrhage is responsible for 91% of preventable prehospital deaths in combat. Bleeding from anatomic junctions such as the groin, neck, and axillae make up 19% of these deaths, and reports estimate that effective control of junctional hemorrhage could have prevented 5% of fatalities in Afghanistan. Hemostatic dressings are effective but are time-consuming to apply and are limited when proper packing and manual pressure are not feasible, such as during care under fire. CounterFlow-Gauze is a hemostatic dressing that is effective without compression and delivers thrombin and tranexamic acid into wounds. Here, an advanced prototype of CounterFlow-Gauze, containing a range of low thrombin doses, was tested in a lethal swine model of junctional hemorrhage. Outcomes were compared with those of Combat Gauze, the current dressing recommended by Tactical Combat Casualty Care. MATERIALS AND METHODS: CounterFlow-Gauze containing thrombin doses of 0, 20, 200, and 500 IU was prepared. Swine received femoral arteriotomies, and CounterFlow-Gauze was packed into wounds without additional manual compression. In a separate study using a similar model of junctional hemorrhage without additional compression, CounterFlow-Gauze containing 500 IU thrombin was tested and compared with Combat Gauze. In both studies, the primary outcomes were survival to 3 h and volume of blood loss. RESULTS: CounterFlow-Gauze with 200 and 500 IU had the highest 3-h survival, achieving 70 and 75% survival, respectively. CounterFlow-Gauze resulted in mean peak plasma tranexamic acid concentrations of 9.6 ± 1.0 µg/mL (mean ± SEM) within 3 h. In a separate study with smaller injury, CounterFlow-Gauze with 500 IU achieved 100% survival to 3 h compared with 92% in Combat Gauze animals. CONCLUSIONS: An advanced preclinical prototype of CounterFlow-Gauze formulated with a minimized thrombin dose is highly effective at managing junctional hemorrhage without compression. These results demonstrate that CounterFlow-Gauze could be developed into a feasible alternative to Combat Gauze for hemorrhage control on the battlefield.


Hemostatics , Tranexamic Acid , Animals , Swine , Thrombin/therapeutic use , Tranexamic Acid/pharmacology , Tranexamic Acid/therapeutic use , Hemostatic Techniques , Disease Models, Animal , Hemorrhage/drug therapy , Hemostatics/pharmacology , Hemostatics/therapeutic use , Bandages , Blindness
16.
Scand J Trauma Resusc Emerg Med ; 31(1): 75, 2023 Nov 09.
Article En | MEDLINE | ID: mdl-37946246

BACKGROUND: Hemorrhage has always been the focus of battlefield and pre-hospitalization treatment. With the increasing fatality rates associated with junctional bleeding, treatment of bleeding at junctional sites has gradually gained attention in battlefield trauma emergency care. We designed a modified chain-based sponge dressing with a medical polyvinyl alcohol sponge that can be used to treat junctional hemorrhage and tested its hemostatic efficacy and biocompatibility. METHODS: Twenty adult Bama miniature pigs were randomly divided into the modified chain-based sponge dressing (MCSD) and standard gauze (SG) groups. The right femoral artery of the pigs was shot at after anesthesia. The Bama miniature pigs were moved to the safety zone immediately to assess the condition according to the MARCH strategy, which evaluates massive hemorrhaging, airway obstruction, respiratory status, circulatory status, head injury & hypothermia. Hemoglobin and coagulation status were checked during the experiment.Among the pigs in which the inguinal hemorrhagic model based on bullet penetrating wounds was successfully established, those in the MCSD group received a disinfected MCSD for hemostasis, while those in the SG group received standard gauze in an imbricate manner to pack the bullet exit and entrance wounds to stop bleeding until the wound was filled, followed by compression for 3 min at sufficient pressure. CT scanning, transmission electron microscopy, and HE staining were conducted after experiment. RESULTS: The MCSD group showed lower hemostasis time and blood loss than the gauze group. The MCSD group also showed a higher success rate of treatment,more stable vital signs and hemoglobin level. The CT scanning results showed tighter packing without large gaps in the MCSD group. The histopathological assessments and the transmission electron microscopy and HE staining findings indicated good biocompatibility of the polyvinyl alcohol sponge. CONCLUSION: The MCSD met the battlefield's requirements of speedy hemostasis and biosafety for junctional hemorrhage in Bama miniature pigs. Moreover, in comparison with the conventional approach for hemostasis, it showed more stable performance for deep wound hemostasis. These findings provide the theoretical and experimental basis for the application of MCSD in the treatment of hemorrhage in the battlefield in the future.


Hemostatics , Polyvinyl Alcohol , Animals , Swine , Swine, Miniature , Bandages , Hemorrhage/therapy , Hemostatics/therapeutic use , Femoral Artery/injuries , Hemoglobins , Disease Models, Animal , Hemostatic Techniques
17.
Am J Obstet Gynecol MFM ; 5(12): 101185, 2023 12.
Article En | MEDLINE | ID: mdl-37832647

The number of cases of placenta accreta spectrum disorder has been increasing with the increase in in vitro fertilization and cesarean deliveries. In addition, placenta accreta spectrum without placenta previa is difficult to diagnose before delivery and sometimes requires a hysterectomy because of heavy bleeding. We have devised a uterus-preserving technique (referred to as the tourniquet, uterine inversion, and placental dissection procedure) for such cases. First, the bleeding is stopped by the tourniquet method, the uterus is relaxed with nitroglycerin, and the uterus is inverted to expose the adhesion site. After that, the placenta is detached by sharp dissection under direct visualization, and the detached areas are sutured, and then the tourniquet and internal rotation are released. This technique does not require advanced skills. Thus, a surgeon could avoid performing a hysterectomy and have a greater chance of uterus preservation when encountering massive hemorrhage caused by unpredictable placenta accreta spectrum without placenta previa in either cesarean deliveries or vaginal deliveries.


Placenta Accreta , Placenta Previa , Uterine Inversion , Female , Pregnancy , Humans , Placenta Accreta/diagnosis , Placenta Accreta/surgery , Placenta Previa/diagnosis , Placenta Previa/epidemiology , Placenta Previa/surgery , Placenta , Tourniquets , Hemostatic Techniques , Fertility
18.
Am J Cardiol ; 209: 181-183, 2023 12 15.
Article En | MEDLINE | ID: mdl-37863115

Suture-mediated closure device and Figure-of-Eight suture are commonly used to achieve hemostasis after use of large bore venous access. Although both methods of closure are commonly used in clinical practice, a head-to-head comparison in a controlled setting has not been performed. Patients presenting to a single center for elective left atrial appendage occlusion or transcatheter edge-to-edge mitral valve repair were randomized to large bore venous closure using the Perclose ProGlide suture-based closure or a Figure-of-Eight suture closure. The patients were followed for 1 month after the procedure. Primary outcome, a composite of access site large ecchymosis, hematoma, infection, pain, need for unscheduled venous ultrasound and need for transfusion, was compared between the 2 arms. A total of 40 patients were randomized in a 1:1 fashion to the 2 venous closure strategies. Baseline characteristics were similar between the 2 groups. Perclose ProGlide arm required use of more devices for hemostasis (1.5 ± 0.5 vs 1 ± 0 respectively, p <0.0001), and there was a significant difference in the cost of closure device ($367.00 ± 122.00 vs $1.00 ± 0 respectively, p <0.001). At 1 month post-procedure, the primary outcome occurred in 4 patients (20%) in the Perclose arm and 7 (35%) patients in the Figure-of-Eight arm, a difference that was not statistically significant (p = 0.48). Time to hemostasis between Figure-of-Eight and Perclose arms did not reach statistical significance (2.5 ± 2.1 vs 3.7 ± 2.3, p = 0.09). In conclusion, both Perclose ProGlide suture-based device and Figure-of-Eight closure are equally feasible and safe for patients who underwent large bore venous access. Figure-of-Eight-based closure is more cost effective.


Hemostasis, Surgical , Vascular Closure Devices , Humans , Femoral Artery/surgery , Hemostasis , Hemostasis, Surgical/methods , Hemostatic Techniques , Suture Techniques , Sutures , Treatment Outcome , Vascular Surgical Procedures
19.
Cardiovasc Intervent Radiol ; 46(11): 1553-1561, 2023 Nov.
Article En | MEDLINE | ID: mdl-37828234

PURPOSE: This study aimed to compare a dual Proglide strategy versus a combination of one Proglide and dual Exoseal for large-bore access closure during percutaneous access endovascular aneurysm repair (pEVAR). MATERIALS AND METHODS: We retrospectively analyzed 97 patients who underwent pEVAR at our center between January 2021 and February 2023. The patients were divided into two groups: dual Proglide (P + P) and one Proglide with dual Exoseal (P + E). The primary outcome measures were technical success and access-related vascular complications. Technical success was defined as achieving complete hemostasis without a bailout strategy. Postprocedural follow-up for access-related vascular complications was evaluated at 30 and 60 days using computed tomography angiography and ultrasonography. Severity was graded according to the Cardiovascular Interventional Radiological Society of Europe (CIRSE) Classification. RESULTS: Overall, a dual Proglide strategy was used in 46 patients (47.4%) with 65 groins (46.4%), and a combination of one Proglide and dual Exoseal was used in 51 patients (52.6%) with 75 groins (53.6%). The baseline characteristics were similar between the groups. The total technical success rate was 96.4%, and no significant differences were observed (95.4% vs. 97.3%; p = 0.870). Minor bleeding treatable through compression occurred significantly more often in the P group (CIRSE 1, 10.8% vs. 1.3%, p = 0.042). Hemostasis time, procedural time, length of stay in the hospital, closure device failure, and incidence of unplanned intervention did not differ significantly between the groups. CONCLUSIONS: A combined Proglide and Exoseal strategy is safe and effective for large-bore access closure during pEVAR and can be considered an alternative. However, it should be supported by larger prospective studies.


Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Vascular Closure Devices , Humans , Aortic Aneurysm, Abdominal/surgery , Endovascular Aneurysm Repair , Prospective Studies , Retrospective Studies , Treatment Outcome , Hemostasis , Sutures , Femoral Artery/surgery , Hemostatic Techniques
20.
Pediatr. aten. prim ; 25(99)3 oct. 2023. tab, ilus
Article Es | IBECS | ID: ibc-226246

El sangrado gastrointestinal es un motivo de consulta frecuente, tanto en los servicios de urgencias hospitalarios como en Atención Primaria. Existen múltiples etiologías que lo pueden motivar. La lesión de Dieulafoy es una causa rara pero potencialmente grave de hemorragia digestiva. Su localización más frecuente es el estómago. Clínicamente se expresa en forma de: melena, hematemesis o hematoquecia. Para su diagnóstico se pueden utilizar diversas exploraciones complementarias, como la angiografía, el angio-TC o la endoscopia. El tratamiento en casos recurrentes consiste en realizar embolización a través de un cateterismo intervencionista (AU)


Gastrointestinal bleeding is a common reason for consultation, both in hospital emergency services and in Primary Care. There are multiple etiologies that can motivate it. Dieulafoy's lesion is a rare but potentially serious cause of gastrointestinal bleeding. Its most common location is the stomach. Clinically it is expressed in the form of: melena, hematemesis or hematochezia. Various complementary exams can be used for its diagnosis, such as angiography, angio-CT or endoscopy. Recurrent bleeding treatment consists of embolization through interventional catheterization. (AU)


Humans , Male , Adolescent , Gastrointestinal Hemorrhage/diagnosis , Gastrointestinal Hemorrhage/therapy , Hemostatic Techniques , Gastrointestinal Hemorrhage/etiology , Angiography
...